On each rising edge with valid=1, treat data as the next MSB-first message bit. Use polynomial 0x1021, initial value 0xFFFF, with no reflection or final XOR.
reset is synchronous and active high; it restores 0xFFFF.valid=0, the CRC holds its value.crc exposes the current value after each edge.